Solutions — ventilation, air conditioning and refrigeration contractors

Vibration isolators for ventilation, air conditioning and refrigeration

Rooftop units, fans, chillers, compressors: every piece of rotating equipment transmits vibration to the building unless it is isolated. Deflection supplies rails, floor isolators, hangers and duct silencers, with a technical sheet for every product.

Your situation

What you need to solve

A rooftop unit that makes the roof vibrate

Aluminum anti-vibration rails, made in Quebec, for all rooftop unit models.

Heavy equipment sitting on the floor

Seismic spring isolators from 25 to 5,600 lb per isolator.

A suspended fan or duct

Spring hangers with a static deflection of 0.5 to 2.25 in depending on the series.

Noise travelling through the ductwork

Custom-built duct silencers: straight, elbow or round.

Products

The products that solve it

Rooftop units

The anti-vibration rail is made of extruded aluminum, top and bottom, and fits all rooftop unit models. It is made in Quebec.

Anti-Vibration Rail

Anti-Vibration Rail

Seismic anti-vibration rails in extruded aluminum, made in Quebec, designed to support rooftop units of all sizes.

View product →

Floor-mounted equipment

Seismic spring isolators cover 25 to 700 lb (SM1), 100 to 2,800 lb (SM2), 200 to 2,800 lb (VSR1) and 400 to 5,600 lb (VSR2). The SM2, VSR1 and VSR2 series have a static deflection of 2 in. The structural steel inertia base, custom-built in Quebec, is supplied with seismic spring isolators calculated for the equipment.

Inertia Base

Inertia Base

Complete structural steel inertia base with reinforcing bars, custom-built in Quebec and supplied with seismic spring isolators calculated for the equipment.

View product →
SM1 Series – Seismic Floor Isolator

SM1 Series – Seismic Floor Isolator

Spring floor isolator with seismic restraint, for floor-mounted mechanical equipment in seismic zones.

View product →
SM2 Series – Seismic Floor Isolator

SM2 Series – Seismic Floor Isolator

SM2 variant of the seismic floor isolator, for loads and configurations different from the SM1.

View product →
VSR1 Series – Seismic Floor Isolator

VSR1 Series – Seismic Floor Isolator

Spring seismic floor isolator, VSR1 configuration.

View product →
VSR2 Series – Seismic Floor Isolator

VSR2 Series – Seismic Floor Isolator

VSR2 variant of the seismic floor isolator.

View product →

Suspended equipment and ducts

SHM spring hangers cover 25 to 660 lb and SHL2 hangers cover 200 to 1,300 lb with a deflection of 2 to 2.25 in. The EHD neoprene hanger covers 33 to 370 lb.

SHM Series – Spring Hanger

SHM Series – Spring Hanger

Spring hanger isolator from the SH family, SHM configuration.

View product →
SHL2 Series – Spring Hanger

SHL2 Series – Spring Hanger

SHL2 variant of the spring hanger isolator with limiter, for loads and applications different from the SHL1.

View product →
SHE1 Series – Spring Hanger

SHE1 Series – Spring Hanger

Spring hanger from the SH family, SHE1 variant, for mechanical equipment suspension applications.

View product →
EHD Series – Neoprene Hanger

EHD Series – Neoprene Hanger

Rubber hanger for hanging ducts, piping and light mechanical equipment.

View product →

Duct and equipment noise

Acoustic silencers are made in Quebec to the criteria of ASTM E477. The acoustic enclosure surrounds the noisy equipment.

Acoustic Silencer

Acoustic Silencer

Custom acoustic silencers compliant with ASTM E477, in galvanized, satin-coat or stainless steel, in straight, elbow or round configurations.

View product →
Acoustic Panels and Sound Barriers

Acoustic Panels and Sound Barriers

Acoustic panels custom-built in Quebec to form a sound barrier around mechanical equipment.

View product →
Acoustic Enclosure

Acoustic Enclosure

Sound enclosures for mechanical equipment (heat pumps, dust collectors, fans) in commercial, industrial or residential settings.

View product →

How it works

From your drawings to delivery

01

Send us your drawings and specifications

Through the form below or by email, with the list of equipment to isolate or the noise problem to solve.

02

Get a quote within 24-48 business hours

With the technical sheets of the proposed products, ready to submit for approval.

03

Delivery or turnkey project

We supply the products, or we take charge of the project through to installation.

Request a quote

Describe your project — a specialist replies within 24-48 business hours.

Frequently asked questions

Ventilation, air conditioning and refrigeration

How do I isolate vibration from a rooftop unit?

The Deflection anti-vibration rail is designed for rooftop units. It is made of extruded aluminum, top and bottom, fits all rooftop unit models and is made in Quebec.

Which deflection should I choose for a spring isolator?

Deflection is set in the specification by the project engineer, according to the equipment and the structure carrying it. Our spring hangers offer a static deflection of 0.5 to 2.25 in depending on the series; SM2, VSR1 and VSR2 seismic floor isolators offer 2 in.

How do I reduce fan noise in the ductwork?

An acoustic silencer installed in the duct treats the noise travelling through it. Deflection silencers are custom-built in Quebec to the criteria of ASTM E477, in three shapes: straight, elbow and round.

How quickly will I receive a quote?

We reply to your drawings and specifications within 24-48 business hours. Send us the equipment list and the specification requirements: the quote comes with the technical sheets of the proposed products.

Who we work with